CanogaOS Command Reference
10-2
10.2 Configuring the CFM frame ethertype
Use the command to configure the ethertype for CFM frames.
Command Syntax
ethernet cfm type TYPE
no ethernet cfm type
Command Mode
Configure mode
Default
The default ethertype is 0x8902.
Usage
The Ethernet type of the CFM frames. The default value is 0x8902.
Examples
Switch#configure terminal
Switch(config)# ethernet cfm type 8902
Switch#configure terminal
Switch(config)# no ethernet cfm type
Related Commands
10.3 Creating a Maintenance Domain
Use the command to create an MD within which you can manage Ethernet traffic. Ensure you specify the
level for each MD. The levels separate MDs from each other and provide different areas of functionality.
Command Syntax
ethernet cfm domain DOMAIN_NAME level LEVE
no ethernet cfm domain DOMAIN_NAME level LEVE
Command Mode
Configure mode
Default
None