Model 9135 SNMPManaged 10/100/1000Ethernet SwitchUser Manual

Strany 2

EdgeAccess Universal Chassis SystemModel 9135 10/100/10001-21.2 Hardware Management FeaturesThe 9135 includes these hardware features for switch manag

Strany 3 - ATTENCION!

EdgeAccess Universal Chassis SystemModel 9135 10/100/10002-1Chapter 2Setup and InstallationThis section describes how to install the 9135 and the inte

Strany 4

EdgeAccess Universal Chassis SystemModel 9135 10/100/10002-23. On the 100 Base modules, fiber optic interface (9100-44x, -54x, -64x, or -74x), set SW1

Strany 5 - Table of Contents

EdgeAccess Universal Chassis SystemModel 9135 10/100/10002-3Table 3. SW1 Settings, 1000 Base Modules, Fiber Optic InterfaceSwitch Name On Off1-1 LLF

Strany 6 - List of Figures

EdgeAccess Universal Chassis SystemModel 9135 10/100/10002-4Dirty optical connectors are a common cause of link loss or attenuation problems, especial

Strany 7 - List of Tables

EdgeAccess Universal Chassis SystemModel 9135 10/100/10002-5Table 5. 9135 Interface Module LEDsLED Status IndicatesTx (Transmit) Off No transmit acti

Strany 8

EdgeAccess Universal Chassis SystemModel 9135 10/100/10002-6

Strany 9 - Overview

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-1Chapter 3ManagementConfigure the 9135 through the management software. For your first ses

Strany 10

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-2Messages andurgent statusScreen navigationinstructionsChange optionsStatus reportsModel nu

Strany 11 - Setup and Installation

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-3Main Menu1. System2. Switch Configuration3. Port Information4. Reports5. Diagnostics6. Res

Strany 13

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-4Table 7. System Menu OptionsMenu Item Description1. IP Settings Set the IP parameters2.

Strany 14 - 2.2 LEDs

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-5Table 8. IP Settings Menu OptionsMenu Item Description1. Local IP AddressSet the network

Strany 15

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-63.4.2 Host Table / SNMP SettingsUse the Host Table and SNMP Settings menu to set access le

Strany 16 - Model 9135 10/100/1000

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-7HOST Table/SNMP SettingsSNMP Access Trap TrapIP Address Access Level Community Port1. 172.

Strany 17 - Chapter 3

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-8Slip Port SettingsTerminal Type: : VT1001. Interface2. Init Modem At Startup3. Modem Init

Strany 18 - Please Enter Login Password:

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-93. At the prompt, type the new password, up to 18 characters, then type it again to confir

Strany 19 - 3.4 System Menu

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-10Menu and Selection Minimum Access Menu and Selection Minimum AccessHost Table / SNMP Se

Strany 20 - 3.4.1 IP Settings

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-11ACEBD123456A small test networkACEBD123456Spanning Tree from source (C)Figure 14. Typica

Strany 21

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-12Global Spanning Tree Parameters1. Enable Spanning Tree :2. Priority :3. Hello Time (sec)

Strany 22

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-13Global Spanning Tree ParametersState : forwardingDesignated Root : 00 00 00 00 00 00 00 0

Strany 23 - 3.4.3 SLIP Port Settings

EdgeAccess Universal Chassis SystemModel 9135 10/100/1000iCAUTION!This product may contain a laser diode operating at a wavelength of 1300nm - 1600nm.

Strany 24 - 3.4.4 Passwords

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-143.5.3 Spanning Tree ReportThe Spanning Tree Report screen shows the current conditions fo

Strany 25 - Notes on Password Protection

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-153.6 Port InformationThe various Port Information and Statistics screens shows status for

Strany 26 - 2. Main Menu

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-16Port 1 InformationLink : yes LLF Hw Switch : disabledFrames Received : 282356856 AUT Hw S

Strany 27 - 4. Main Menu

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-173.7 ReportsThe Reports Menu provides access to a brief description of the 9135, the traps

Strany 28

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-18Traps LogCount Time 0 days 00:11:07 Trap Type1 0 days 00:00:00 Cold Start ()2 0 days 00:0

Strany 29

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-19Fdb LogCount MAC Port Status109 00 C0 EE D0 90 5B 1 learned110 00 D0 B7 47 BD 58 1 learne

Strany 30 - 3.5.3 Spanning Tree Report

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-20Ping1. Ping Address2. Ping Count3. Start Pinging4. Main MenuFigure 28. Ping Menu3.9 Rest

Strany 31 - 3.6 Port Information

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-21Restart System1. System2. Switch Configuration3. Port Information4. Reports+-------------

Strany 32

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-227. Start the download. The process sends the upgrade directly to the inactive Flash loca

Strany 33 - 3.7.2 Traps Log Screen

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-2313. When the transfer is complete, a successful message appears. At the prompt, enter qu

Strany 34 - 3.7.3 Fdb Log Screen

EdgeAccess Universal Chassis SystemModel 9135 10/100/1000iiNOTICECanoga Perkins has prepared this users manual for use by customers and Canoga Perkins

Strany 35 - 3.8 Diagnostics

EdgeAccess Universal Chassis SystemModel 9135 10/100/10003-24

Strany 36 - 3.10 Restart Unit

EdgeAccess Universal Chassis SystemModel 9135 10/100/10004-1Chapter 4SLIP ConnectionYou can connect a dial-up modem to the DCE port on the SNMP Manage

Strany 37 - 3.11 Logout

EdgeAccess Universal Chassis SystemModel 9135 10/100/10004-26. On the Basic tab, enter a name and the phone number for the 9135, then from the Dial us

Strany 38

EdgeAccess Universal Chassis SystemModel 9135 10/100/10005-1Chapter 5Specifications5.1 Switch SpecificationsSwitching CharacteristicsBridging: Per IEE

Strany 39

EdgeAccess Universal Chassis SystemModel 9135 10/100/10005-25.2 9135 Ports and PinoutsTable 17. Terminal Port, Female DE-9Pin Signal1, 4, 8, 9 Not Us

Strany 40

EdgeAccess Universal Chassis SystemModel 9135 10/100/10005-35.3 Regulatory Compliance and Referenced DocumentsComplies with these regulations:• ETL,

Strany 41 - SLIP Connection

EdgeAccess Universal Chassis SystemModel 9135 10/100/10005-4100BASE FX Fiber Optic Field-Interchangeable Interfaces9100-441 100BASE FX 1310 nm MM LED

Strany 42

EdgeAccess Universal Chassis SystemModel 9135 10/100/10005-510 BASE FL SM 20 dBEmitter Type: Laser diodeWavelength: 1310 nm nominalReceive Sensitivity

Strany 43 - Specifications

EdgeAccess Universal Chassis SystemModel 9135 10/100/10005-6100 BASE FX SM 10 dBEmitter Type: Laser diodeWavelength: 1310 nm nominalReceive Sensitivit

Strany 44 - 5.2 9135 Ports and Pinouts

EdgeAccess Universal Chassis SystemModel 9135 10/100/10005-7Gigabit Single Mode (SM) 1310 nm LXEmitter Type: Laser DiodeWavelength: 1310 nm nominalRec

Strany 45 - 5.4 Interfaces and Connectors

EdgeAccess Universal Chassis SystemModel 9135 10/100/1000iiiTable of Contents Chapter 1 Overview ...

Strany 46

EdgeAccess Universal Chassis SystemModel 9135 10/100/10005-8

Strany 47

EdgeAccess Universal Chassis SystemModel 9135 10/100/1000A-1Appendix AWarrantyLimited Lifetime WarrantyEffective July 1, 2005 and After, Canoga Perkin

Strany 48

EdgeAccess Universal Chassis SystemModel 9135 10/100/1000A-2LimitationsCanoga Perkins may at its sole discretion modify its Limited Warranty at any ti

Strany 49

EdgeAccess Universal Chassis SystemModel 9135 10/100/1000B-1Appendix BAcronymsBOOTP Boot Protocol (a TCP/IP protocol)BPDU Bridge Protocol Data UnitCTS

Strany 50

CANOGA PERKINS CORPORATION20600 Prairie StreetChatsworth, California 91311-6008 USAPhone: (818) 718-6300 FAX: (818) 718-6312Web Site: www.canog

Strany 51 - Warranty

EdgeAccess Universal Chassis SystemModel 9135 10/100/1000iv Appendix A Warranty...

Strany 52 - Return Policy

EdgeAccess Universal Chassis SystemModel 9135 10/100/1000vList of TablesTable 1. SW1 Settings, UTP Copper Interface ...

Strany 53 - Acronyms

EdgeAccess Universal Chassis SystemModel 9135 10/100/1000vi

Strany 54

EdgeAccess Universal Chassis SystemModel 9135 10/100/10001-1Chapter 1OverviewThe Canoga Perkins EdgeAccess 9135 is an SNMP Managed, two-port Ethernet

Komentáře k této Příručce

Žádné komentáře