Shrnutí obsahu

Strany 1 - User Manual

Model 9135G SNMP Managed Gigabit Ethernet Switch User Manual

Strany 2 - NOTICE!

EdgeAccess Ethernet Switch 2.2.2 Standalone When using the 9135G as a standalone unit, place it on a secure, flat surface. Ensure that the 9135G is

Strany 3

EdgeAccess Ethernet Switch 2.3.2 DC Power Entry The connection for the -48VDC power supply is detailed in Figure 3. -VDC Terminal for negative le

Strany 4 - Table of Contents

EdgeAccess Ethernet Switch 2.4 Relay Contacts The alarm contacts for the 9135G are located next to the SLIP Port on the rear panel and are shown in F

Strany 5 - List of Figures

EdgeAccess Ethernet Switch 2.6.1 Management Access --Terminal The Terminal Port (EIA 232), located on the rear panel of the 9135G, provides access to

Strany 6 - List of Tables

EdgeAccess Ethernet Switch 2.6.2 Management Access - Modem SLIP Connection The SLIP Port, located on the rear panel of the 9135G, provides a modem co

Strany 7 - Overview

EdgeAccess Ethernet Switch 2.7 LED Indicators The 9135G incorporates four LED indicators. The interface modules incorporate eight LED indicators. 2.

Strany 8

EdgeAccess Ethernet Switch 2.7.2 9135G Interface LEDs Table 2. 9135G Interface LEDs LED Status Description Tx (Transmit) Off No transmit activit

Strany 9 - Setup and Installation

EdgeAccess Ethernet Switch Chapter 3 Management Configure the 9135G management program for the environment where it will be used (IP address, Gateway

Strany 10 - • Fiber optic connections

EdgeAccess Ethernet Switch • Highlight Programs, then Accessories, then the HyperTerminal folder, and click on HyperTerminal. The Connection Descript

Strany 11 - 2.3.2 DC Power Entry

EdgeAccess Ethernet Switch • Enter the COM Port parameters as shown in Figure 12. • Bits per second: 9600 • Data bits: 8 • Parity: None • Stop b

Strany 12 - 2.5 Installing Modules

EdgeAccess Ethernet Switch CAUTION! This product may contain a laser diode operating at a wavelength of 1300nm - 1600nm. Use of optical instrum

Strany 13

EdgeAccess Ethernet Switch 3.2 Operation of the 9135G Management Program The first screen that will come up will be the Login Menu. If this is your i

Strany 14 - 2.6.3 Fiber Optic Cabling

EdgeAccess Ethernet Switch When the Main Menu screen appears, select a screen to set up, monitor, or change system settings for the Switch configurati

Strany 15 - 2.7.1 9135G LEDs

EdgeAccess Ethernet Switch Figure 15. System Menu 3.2.1.1 IP Settings This screen lists all the Internet Protocol (IP) settings and configuration

Strany 16 - 2.7.2 9135G Interface LEDs

EdgeAccess Ethernet Switch Table 5. Agent IP Address First Octet of Agent IP Address Default Subnet Mask Class A 1-126 255.0.0.0 Class B 128-191 *

Strany 17 - Management

EdgeAccess Ethernet Switch Figure 17. Host Table / SNMP Settings Items 1-8: • To add an IP address to the Host Table or change SNMP Settings, sele

Strany 18

EdgeAccess Ethernet Switch Items 11-14: Item 11: Send Alert Traps select "11," press the <space bar> to toggle between Yes and No, t

Strany 19

EdgeAccess Ethernet Switch • SLIP IP Address enter the IP address of the Serial Line Interface Port. The SLIP and in-band addresses must be on diffe

Strany 20

EdgeAccess Ethernet Switch Technical notes on Password Protection: When logging on, if the password string matches the supervisor string, you are log

Strany 21 - 3.2.1 System Menu

EdgeAccess Ethernet Switch MENU and SELECTION MINIMUM ACCESS LEVEL SLIP Port Setup Menu Baud Rate Supervisor Parity Supervisor Stop Bit

Strany 22

EdgeAccess Ethernet Switch Figure 20. Switch Configuration Menu 3.2.2.1 Spanning Tree Ethernet bridges or switches use the Spanning Tree Protoco

Strany 23

EdgeAccess Ethernet Switch NOTICE Canoga Perkins has prepared this users manual for use by customers and Canoga Perkins personnel as a guide for the p

Strany 24

EdgeAccess Ethernet Switch When Spanning Tree is enabled, the 9135G monitors the incoming data packets while sending out Bridge PDUs (Protocol Data

Strany 25

EdgeAccess Ethernet Switch 3.2.2.2 Global Spanning Tree Parameters To enable the Spanning Tree function, select "1" or "Spanning Tree&q

Strany 26

EdgeAccess Ethernet Switch 3.2.2.3 Port Spanning Tree Parameters Use the Port Spanning Tree Parameters screen to view and configure certain Port Spann

Strany 27

EdgeAccess Ethernet Switch Configurable parameters • Change Port select a port to view or change the parameters. • Priority priority of the port; t

Strany 28 - 3.2.2 Switch Configuration

EdgeAccess Ethernet Switch • Hello Time (sec) the time between the generation of BPDUs by the root. The parameters is used if the bridge become the

Strany 29

EdgeAccess Ethernet Switch 3.2.3 Port Information The Port Information screen shows the individual or cumulative status of each 9135G Port. It opens

Strany 30

EdgeAccess Ethernet Switch 3.2.4 Reports The Reports Menu provides access to a brief description of the 9135G, the traps log, and the Fdb Log table.

Strany 31

EdgeAccess Ethernet Switch 3.2.4.2 Traps Log Screen The Traps that can be reported are predefined. The Traps Log screen reports each trap that occurre

Strany 32

EdgeAccess Ethernet Switch These traps will be reported: • Cold Start • Warm Start • Link Up • Link Down • Authentication Fail • EGP Neighbor L

Strany 33

EdgeAccess Ethernet Switch 3.2.5.1 Ping Ping is a diagnostic routine that sends a signal (Ping) to a known remote unit that can receive it and return

Strany 34

EdgeAccess Ethernet Switch Table of Contents TABLE OF CONTENTS ...

Strany 35 - 3.2.3 Port Information

EdgeAccess Ethernet Switch 3.2.6 Restore Defaults Select 6 on the Main Menu to restore all configurable settings to factory defaults except for: • I

Strany 36 - 3.2.4 Reports

EdgeAccess Ethernet Switch 3.2.8 Logout When passwords are set, for security purposes, log out at the end of each session. Select 8 from the Main Menu

Strany 37

EdgeAccess Ethernet Switch 3.3 How to Update the 9135G Manager Software Through TFTP To verify the software revision currently stored in the Flash me

Strany 38 - 3.2.5 Diagnostics

EdgeAccess Ethernet Switch 3.4 How to Update the 9135G Manager Software Through FTP To verify the software revision currently stored in the Flash mem

Strany 39

EdgeAccess Ethernet Switch This page is intentionally left blank. Model 9135G SNMP Managed Gigabit Ethernet Switch 3-28

Strany 40 - 3.2.7 Restart Unit

EdgeAccess Ethernet Switch Chapter 4 SLIP Instructions EdgeAccess Application with SNMP via SLIP The 9135G Serial Line IP support allows you to atta

Strany 41 - 3.2.8 Logout

EdgeAccess Ethernet Switch Figure 36. SLIP Port Settings Verify the following settings: • Interface: modem • Init Modem At Startup: Yes • Mo

Strany 42

EdgeAccess Ethernet Switch Figure 37. Windows NT Control Panel with Modem Icon Selected. Step 2 Confirm that a modem is installed, as shown in F

Strany 43

EdgeAccess Ethernet Switch Step 3 Confirm that the modem is set to maximum speed as shown in Figure 39. For details, refer to the modem manual. F

Strany 44

EdgeAccess Ethernet Switch Follow the next steps to install the SLIP drivers and configure TCP/IP. Ste desktop, double-click My Computer, then double

Strany 45 - SLIP Instructions

EdgeAccess Ethernet Switch 5.2 Switching Characteristics ...

Strany 46

EdgeAccess Ethernet Switch Figure 43. New Phonebook Entry Step 8 Click the Server tab. From the Dial-Up Server Type drop down menu, select "

Strany 47

EdgeAccess Ethernet Switch Figure 45. SLIP TCP/IP Settings. Step 10 Select the Script tab. Click Pop up a terminal window. Click OK. Figure 46

Strany 48

EdgeAccess Ethernet Switch Step 11 In the Dial-Up Networking window, check that the new properties are correct, then plug a phone line into the comput

Strany 49

EdgeAccess Ethernet Switch Figure 49. Initiating Telnet Session in MSDOS Step 14 From the Connect menu, select Remote Syst

Strany 50

EdgeAccess Ethernet Switch Figure 51. Successful Telnet Session Model 9135G SNMP Managed Gigabit Ethernet Switch 4-10

Strany 51

EdgeAccess Ethernet Switch Chapter 5 Specifications 5.1 9135G Ports Table 6. Fiber Optic Ports: (Extension and User) Model Number Description 850n

Strany 52

EdgeAccess Ethernet Switch Female Male Terminal SLIP Figure 52. Terminal/SLIP Port Connectors. 5.2 Switching Characteristics Technology:

Strany 53

EdgeAccess Ethernet Switch 5.2.1 Management Board – Characteristics In-Band Support: SNMP, TELNET, TFTP, BOOTP MIBs Supported: MIB II, Bridge

Strany 54

EdgeAccess Ethernet Switch 5.5 Physical / Environmental Dimensions: 17.25"W x 13.375"L x 1.75"H [1U] 438mm W x 340mm L

Strany 55 - Specifications

EdgeAccess Ethernet Switch 5.9 Optical Connector SC physical connector provided 5.10 Optical Interface Specification Gigabit Multimode (MM) 850nm

Strany 56

EdgeAccess Ethernet Switch Figure 34. Software Revision Check...

Strany 57 - • Remote Fault

EdgeAccess Ethernet Switch Gigabit Single Mode (SM) 1310nm LD (DFB) Emitter Type: Laser Diode Wavelength: 1310nm nominal Transmit Power:

Strany 58 - 5.8 Power

EdgeAccess Ethernet Switch Chapter 6 Acronyms Acronym List AC = Alternating Current API = Application Programming Interface ASCII = Ameri

Strany 59 - 5.9 Optical Connector

EdgeAccess Ethernet Switch LLFen = Link Loss Forwarding Enable Lnk = Link MAC = Media Access Control MB = Megabyte (≈1,000,000 bytes) Mb

Strany 60

EdgeAccess Ethernet Switch Appendix A Warranty Limited Lifetime Warranty Effective July 1, 2005 and After, Canoga Perkins warrants that, at the time

Strany 61 - Acronyms

EdgeAccess Ethernet Switch Limitations Canoga Perkins may at its sole discretion modify its Limited Warranty at any time and from time to time. Other

Strany 63 - Warranty

CANOGA PERKINS CORPORATION 20600 Prairie Street Chatsworth, California 91311-6008 USA Phone: (818) 718-6300 FAX: (818) 718-6312 W

Strany 64 - Return Policy

EdgeAccess Ethernet Switch Chapter 1 Overview The Canoga Perkins EdgeAccess 9135G is an SNMP Managed, two-port Gigabit Ethernet Switch that provides

Strany 65

EdgeAccess Ethernet Switch • Address table supports 1,000 entries • Alarm relay contacts connector per port link status Management Features: • In

Strany 66

EdgeAccess Ethernet Switch Chapter 2 Setup and Installation This section describes how to install and operate the 9135G. The 9135G can be installed i

Komentáře k této Příručce

Žádné komentáře