Standalone Version i
CanogaView® Smart Element Manager4 Standalone VersionIn addition, the CanogaView Smart Element Manager’s SNMP Agent Chooser applicationmust be used to
CanogaView® Smart Element ManagerStandalone Version5Chapter 2 Installing CanogaView Smart Element ManagerAll files necessary for the installation of t
CanogaView® Smart Element Manager6 Standalone VersionFigure 2-2: Netscape Navigator Java Enable Example2.2 Installation Steps2.2.1 Insert CD or Select
CanogaView® Smart Element ManagerStandalone Version72.2.2 InstallAnywhere Security WarningIf prompted with a security warning, as seen below, allow &q
CanogaView® Smart Element Manager8 Standalone VersionFigure 2-4: Installer for Windows
CanogaView® Smart Element ManagerStandalone Version92.2.4 Progress MeterThe installation process will prepare the installation by extracting data from
CanogaView® Smart Element Manager10 Standalone VersionWhen the “OK” button is selected, the installation process continues and the followingscreens ar
CanogaView® Smart Element ManagerStandalone Version112.2.7 License AgreementNext, the Canoga Perkin’s License agreement is displayed. You must “accept
CanogaView® Smart Element Manager12 Standalone Version2.2.8 Important InformationNext, the Important Information screen is displayed. It is important
CanogaView® Smart Element ManagerStandalone Version132.2.9 Choose Install FolderThe first configurable installation screen that you will encounter is
CanogaView® Smart Element Managerii Standalone VersionNOTICECanoga Perkins has prepared this users manual for use by customers and Canoga Perkinsperso
CanogaView® Smart Element Manager14 Standalone Version2.2.10 Choose Shortcut LocationThe "Choose Shortcut Location" screen defines where ap
CanogaView® Smart Element ManagerStandalone Version152.2.11 Enter SNMP Trap PortThe "Enter SNMP Trap Port" screen allows the selection of a
CanogaView® Smart Element Manager16 Standalone Version2.2.12 Installation BillboardsNext, as series of billboard messages will be displayed during th
CanogaView® Smart Element ManagerStandalone Version172.2.13 Installation CompleteFigure 2-14: Installation Complete
CanogaView® Smart Element Manager18 Standalone Version
CanogaView® Smart Element ManagerStandalone Version19Chapter 3Using CanogaView Smart Element ManagerThis chapter provides an overview of the CanogaVie
CanogaView® Smart Element Manager20 Standalone VersionCanogaView Smart Element Manager Application HierarchyNotesCanogaView Smart Element Manager Home
CanogaView® Smart Element ManagerStandalone Version21 à 5U Chassis ViewGraphical display for an individual 5U Chassis
CanogaView® Smart Element Manager22 Standalone Version à Status à Config
CanogaView® Smart Element ManagerStandalone Version23enhancements and known problems à Installation NotesInstallation notes for Windows, Sun an
CanogaView® Smart Element ManagerStandalone VersioniiiTable of ContentsChapter 1 System Requirements...
CanogaView® Smart Element Manager24 Standalone VersionClose Windows - close all displayed windows except for the window on which thisicon appears.Exit
CanogaView® Smart Element ManagerStandalone Version25• Server platform access only as the client CanogaView Smart Element Managerapplications must be
CanogaView® Smart Element Manager26 Standalone Version3.2 Getting StartedOnce CanogaView Smart Element Manager is installed you are ready to start us
CanogaView® Smart Element ManagerStandalone Version273.2.2 Start CanogaView Smart Element ManagerThe CanogaView Start Page provides a starting point f
CanogaView® Smart Element Manager28 Standalone VersionNext, the CanogaView Smart Element Manager Login screen opens and the user will beprompted to en
CanogaView® Smart Element ManagerStandalone Version29The SNMP Agents currently supported are:• Domain Management Module (DMM) for management support
CanogaView® Smart Element Manager30 Standalone VersionFigure 3-11. Add/Edit Agent ScreenField Name UsageIP AddressIP address of the SNMP Agent to be m
CanogaView® Smart Element ManagerStandalone Version31The “Status” column (example below) reports the status of each SNMP Agent being monitored. TheSta
CanogaView® Smart Element Manager32 Standalone VersionThe following figure shows the views that are currently implemented in CanogaView SmartElement M
CanogaView® Smart Element ManagerStandalone Version33Figure 3-14. Domain View.Note the symbols at the bottom of the chassis. There are six symbols:•
CanogaView® Smart Element Manageriv Standalone Version4.8 How do I Uninstall CanogaView Smart Element Manager?... 62
CanogaView® Smart Element Manager34 Standalone VersionChassis ViewChassis View details all modules and LED status within a chassis. Major and minor al
CanogaView® Smart Element ManagerStandalone Version35Figure 3-16. Modem View.
CanogaView® Smart Element Manager36 Standalone VersionDevice (9135G) ViewOnce a 9135G, 9135 or 9140 is selected from the Agent Chooser application, th
CanogaView® Smart Element ManagerStandalone Version373.3 Other Applications3.3.1 Account ManagerTo manage login accounts (e.g., add/delete users, set
CanogaView® Smart Element Manager38 Standalone VersionFigure 3-19: Account ManagerFigure 3-20: Add User
CanogaView® Smart Element ManagerStandalone Version393.3.2 Alarm MonitorEach graphical views have a button with a yellow bell; the Alarm Monitor. The
CanogaView® Smart Element Manager40 Standalone VersionAn example of alarms when selected at the Agent Chooser level is displayed below. Notethat alar
CanogaView® Smart Element ManagerStandalone Version41 Next, an example of selecting the alarm button at a device level follows:Figure 3-22. Alarm Moni
CanogaView® Smart Element Manager42 Standalone VersionFigure 3-23. Alarm Legend
CanogaView® Smart Element ManagerStandalone Version43Alarm Event Queries or Reports - generate HTML reports against the alarm data base byLog Time, So
CanogaView® Smart Element ManagerStandalone VersionvFigure 3-9. Login Screen...
CanogaView® Smart Element Manager44 Standalone VersionFigure 3-26. Example Alarm Report3.3.3 ConfigurationCanogaView Smart Element Manager supports th
CanogaView® Smart Element ManagerStandalone Version45Figure 3-27. 9135G Port Configuration3.3.4 ResetAt various levels the user is able to issue rese
CanogaView® Smart Element Manager46 Standalone VersionFigure 3-28. Fiber Optic Modem Reset ExampleFigure 3-29. 9135G Reset Example
CanogaView® Smart Element ManagerStandalone Version47Figure 3-30. Factory Defaults Confirmation ExampleFigure 3-31. Reset Confirmation Example3.3.5 Re
CanogaView® Smart Element Manager48 Standalone VersionFigure 3-32. Domain Level Reports
CanogaView® Smart Element ManagerStandalone Version49Figure 3-33. Domain Level Report Example
CanogaView® Smart Element Manager50 Standalone VersionFigure 3-34. 9135G Report
CanogaView® Smart Element ManagerStandalone Version513.3.6 Security ManagerCollectively the security features within CanogaView Login, Application Lev
CanogaView® Smart Element Manager52 Standalone VersionFigure 3-35. Security Manager3.3.7 Status
CanogaView® Smart Element ManagerStandalone Version53Although the status of a device is implied at many levels through the use of color, alarms,graphi
CanogaView® Smart Element Managervi Standalone Version
CanogaView® Smart Element Manager54 Standalone VersionFigure 3-37. 9135G Status – General Tab
CanogaView® Smart Element ManagerStandalone Version55Figure 3-38. 9135G Status – Spanning Tree Tab
CanogaView® Smart Element Manager56 Standalone VersionFigure 3-39. 9135G Status – Forwarding Database TabFigure 3-40. 9135G Status – Version Tab
CanogaView® Smart Element ManagerStandalone Version57Figure 3-41. 9135G Port Statistics3.3.8 TelnetTelnet is the supported craft interface for login a
CanogaView® Smart Element Manager58 Standalone VersionFigure 3-42. DMM Telnet Example3.3.9 TFTP ServerThe TFTP Server Utility monitors the TFTP file t
CanogaView® Smart Element ManagerStandalone Version59Figure 3-43. TFTP Server UtilityFigure 3-44. TFTP Help
CanogaView® Smart Element Manager60 Standalone Version
CanogaView® Smart Element ManagerStandalone Version61Chapter 4 Frequently Asked QuestionsThe following list of frequently asked questions is installed
CanogaView® Smart Element Manager62 Standalone Version4.6 How many User Accounts are supported?No limitation. However, the Standalone Version restrict
CanogaView® Smart Element ManagerStandalone Version63This is from the Netscape 6 release notes athttp://home.netscape.com/eng/mozilla/ns6/relnotes/6.0
CanogaView® Smart Element ManagerStandalone Version1Chapter 1 System Requirem entsThe CanogaView Smart Element Manager Server’s hardware and software
CanogaView® Smart Element Manager64 Standalone Version4.15 What is a Domain?In the context of the UCS 2U and 5U chassis; a domain is a set of products
CanogaView® Smart Element ManagerStandalone Version65Chapter 5 TroubleshootingThe following is a list of typical troubleshooting techniques that can b
CanogaView® Smart Element Manager66 Standalone VersionContact technical support with this information for a resolution.5.3 Traps/Alarm ProcessingIf yo
CanogaView® Smart Element ManagerStandalone Version67For each trap received, you should see messages from "TRAPSERVICE" and"EVENTENGINE
CanogaView® Smart Element Manager68 Standalone Version
CanogaView® Smart Element ManagerStandalone Version69Appendix AWarrantyLimited Lifetime WarrantyEffective for Products Shipped February 1, 2003 and Af
CanogaView® Smart Element Manager70 Standalone VersionLimitationsCanoga Perkins may at its sole discretion modify its Limited Warranty at any time and
CANOGA PERKINS CORPORATION20600 Prairie StreetChatsworth, California 91311-6008 USAPhone: (818) 718-6300 FAX: (818) 718-6312Web Site: www.canog
CanogaView® Smart Element Manager2 Standalone Versiondevice that is to be managed. Additionally, if trap/alarm monitoring is desired, then theappropri
CanogaView® Smart Element ManagerStandalone Version3An example of a 9135 Host Table telnet session screen is shown below: (the screens for the9140 and