5.4.2 New Installation
On new installations, make sure that all steps in Chapter 2 are complete, then follow these steps:
1. Check that the STA LED is green.
2. Check that the fiber type (multimode or single mode) matches the 9155 optical mode.
3. Make these checks:
All fiber cabling is of the same type; do not mix multimode and single mode cables.
The fiber optic cable is within the specifications and loss budget of the optic interface
module.
The line length between the 9155 and the remote link does not exceed the allowable loss
budget or overdrive limit.
All host modules in the link are turned on.
All fiber cables are connected Tx to Rx and Rx to Tx.
5.4.3 Problems With Fiber Optics
If a link is down, inspect and clean the cables and connectors, then replace any damaged fiber. Retest
modules after cleaning.